Blog

Case Study: QUIKTRIP 489 (Casa Grande, AZ)

Case Study: QUIKTRIP 489 (Casa Grande, AZ)

Feb 22, 2022

INTRO Project Description The QuikTrip Store 489 project, located in Casa Grande, Arizona was completed April 2022 and is now open. The scope of work included excavation, trenching, backfill, fuel system installation, testing, start-up, and commissioning. DETAILS Project Features Five (5) 15,000 Gallon Underground Storage Tanks (UST) Five (5) single-walled, turbine tank sump Ten (10) Gilbarco Encore 700s Underground Pipe…

Case Study: LEGOLAND Fuel Facility (Carlsbad, CA)

Case Study: LEGOLAND Fuel Facility (Carlsbad, CA)

Feb 15, 2022

INTRO Project Description The LEGOLAND Fuel Facility is located in Carlsbad, CA. The scope of work included the installation of an aboveground fuel system and fuel management system.  DETAILS Project Features One (1) 4,000 Gallon Aboveground Storage Tank (AST) w/ tank top equipment Two (2) Tank Mounted Dispensers One (1) Retractable Hose Reel Two (2) Interstitial Leak Detectors Two (2)…

Case Study: Brown Field Border Patrol Station (Dulzura, CA)

Case Study: Brown Field Border Patrol Station (Dulzura, CA)

Feb 7, 2022

INTRO Project Description The Brown Field Border Patrol Station located in Dulzura, CA is in progress and nearing completion.  The scope of work includes the installation of vehicle service equipment, an aboveground fuel system, fuel system electrical, and start-up and commissioning. DETAILS Project Features Three (3) 240-gallon Double-Wall UL-142 Oil Tanks One (1) 480-gallon Double-Wall UL-142 Oil Tank One (1)…

Senate Bill #445 Storage Tank Regulation

Senate Bill #445 Storage Tank Regulation

Oct 19, 2021

Procore Underground Storage Tank Owners and Operators in the state of California will be faced with a difficult decision come December 31st, 2025. Senate Bill #445 requires single-walled tank owners and operators to permanently close or replace Underground Storage Tanks containing hazardous substances. Operators that refuse to make the changes needed to comply may be red-tagged by the Unified Program…

WESTERN PUMP acquires DOEHRMAN COMPANY, Inc.

WESTERN PUMP acquires DOEHRMAN COMPANY, Inc.

Oct 1, 2021

WESTERN PUMP acquires DOEHRMAN COMPANY, Inc. FOR IMMEDIATE RELEASE: Oct 1, 2021 San Diego, CA  – WESTERN PUMP, Inc., is proud to announce its recent acquisition of DOEHRMAN COMPANY, Inc., and DCI/SOUTHWEST DIRECT-LIFT & GARAGE OUTFITTERS. DOEHRMAN COMPANY, Inc., is the leading automotive service equipment distributor & contractor in the southwestern United States specializing in the design, construction, installation, and…

Case Study: Quiktrip | Single-Compartment Diesel Underground Tank Installation (Chandler, AZ)

Case Study: Quiktrip | Single-Compartment Diesel Underground Tank Installation (Chandler, AZ)

Sep 17, 2021

INTRO Project Description The Brown Field Border Patrol Station located in Dulzura, CA is in progress and nearing completion.  The scope of work includes the installation of vehicle service equipment, an aboveground fuel system, fuel system electrical, and start-up and commissioning. DETAILS Project Features Three (3) 240-gallon Double-Wall UL-142 Oil Tanks One (1) 480-gallon Double-Wall UL-142 Oil Tank One (1)…

Case Study: QuikTrip | Single-Compartment Diesel Underground Tank Installation (Tolleson, AZ)

Case Study: QuikTrip | Single-Compartment Diesel Underground Tank Installation (Tolleson, AZ)

Jul 26, 2021

INTRO Project Description The QuikTrip Store located in Tolleson, Arizona had two (2) 13,000 gallon single-compartment diesel underground storage tanks added to its existing site away from the existing tank farm. The project was completed on July 23, 2021. The scope of work included demolition, excavation and trenching, a diesel tank addition, dispenser removal and installation, backfilling, tank monitor upgrades,…

Case Study: Sea World Underground Storage Tank Replacement (San Diego, CA)

Case Study: Sea World Underground Storage Tank Replacement (San Diego, CA)

Mar 30, 2021

INTRO Project Description SeaWorld San Diego had an existing fuel system that needed updating. Western Pump removed one (1) 10,000 gallon UST system and replaced it with one (1) AB-2481 continuously monitored 10,000 gallon UST system with double wall sumps, product, vent, and vapor piping, electrical controls and monitoring. The project was completed March of 2021 and included demolition, underground…

The Hidden Problem that Could Be Hurting Your Business – Dirty Fuel

The Hidden Problem that Could Be Hurting Your Business – Dirty Fuel

Feb 4, 2021

The hidden problem that could be hurting your business – dirty fuel. Our fuel system service experts have prepared this fuel system cleaning FAQ to help you learn more about this hidden problem and ways to correct it. How do fuel systems accumulate contaminants over time? All fuel tank systems are vented to allow for filling and dispensing. Venting enables…